67
13 Technical Data
CS-PE9DKE / CU-PE9DKE / CS-PE12DKE / CU-PE12DKE
Cooling characteristics
Heating characteristics
Outdoor temp( )
[Condition] Room temp: 27/19
Cooling operation:at high speed
Piping length:7.5m
I: current (A)
Q: Cooling capacity (kW)
Outdoor temp( )
[Condition] Room temp: 27/19
Heating operation:at high speed
Piping length:7.5m
I: current (A)
Q: Heating capacity (kW)
LP:Gas side piping
Pressure (Mpa)
O:Outlet Air temp( )
HP:Gas side piping
Pressure (Mpa)
O:Outlet Air temp( )
4.0
3.0
2.0
3.8
3.6
3.4
3.2
20
18
16
14
12
10
0.9
0.8
0.7
0.6
0.5
30
32
34
36
38
40
42
44
230V
3.4
3.3
3.2
3.1
3.9
3.8
3.7
3.6
39
38
37
36
3.0
2.9
2.8
2.7
5
6
789
10
11 12
230V
Operating characteristics
CS-PE9DKE/CU-PE9DKE
6
5
4
30
32
34
36
38
40
42
44
7
6
5
3.6
3.4
3.2
3.0
2.8
13
12
11
Cooling characteristics
Outdoor temp( )
[Condition] Room temp: 27/19
Cooling operation:at high speed
Piping length:7.5m
I: current (A)
Q: Cooling capacity (kW)
LP:Gas side piping
Pressure (Mpa)
O:Outlet Air temp( )
230V
CS-PE12DKE/CU-PE12DKE
4.4
4.2
4.0
3.8
5.5
5.3
5.1
4.9
4.7
47
46
45
44
43
22
21
20
19
56789
10
11
Heating characteristics
Outdoor temp( )
[Condition] Room temp: 27/19
Heating operation:at high speed
Piping length:7.5m
I: current (A)
Q: Heating capacity (kW)
HP:Gas side piping
Pressure (Mpa)
O:Outlet Air temp( )
230V
Comentarios a estos manuales